Deconvolution of compound responses reveals two firing components invisible in raw waveforms

Evidence

Obviously, there are multiple differences in experimental settings and biology between the guinea pig and human, which may contribute to different CDLD outcomes. Among others, cause of deafness, cochlear anatomy, duration of deafness, and rate of neural degeneration differ, and there is awake vs. anaesthetized state, chronic vs. acute cochlear implantation, and long vs. short electrode array. Taking these differences into account, a few characteristics appeared to be quite robust across species and experimental setting. Importantly, the deconvolution of the eCAP revealed two separate firing components, which could not easily be detected from the eCAP waveforms themselves. The ratio of the components and the latency of the early component came out as potential markers to assess the condition of the auditory nerve. — Dijk, Pim van, Physiology, Psychoacoustics and…, 2445