Sound level meters trade average level against tracking speed via time response.
Evidence
Thus most sound level meters have slow and fast time response settings. The slow time response gives an estimate of the average sound level whereas the fast response tracks more rapid variations in the sound pressure level. — David Howard, Jamie Angus, coustics and Psychoacoustics, 627
Categorization
- CANDY: ‘Fast’ and ‘slow’ on a sound meter are literally averaging speeds — quick, tweetable.
- factual_claims: It reports the actual slow and fast time-response settings on sound level meters and what each measures.
- XREF: connects to: Sound level meters need time averaging to estimate varying pressure levels — David M. Howard, Jamie Angus, Acoustics and Psychoacoustics, 637; Slow and fast meter responses trade averaging for capturing rapid level changes; Different hearing tasks exploit different model time constants. — Ville Pulkki, Matti Karjalainen, Communication Acoustics- An…, 1628 (+2 more)
Broader Connections
- Slow and fast meter responses trade averaging for capturing rapid level changes
#expands(0.90) - Sound level meters need time averaging to estimate varying pressure levels
#expands(0.85) — David M. Howard, Jamie Angus, Acoustics and Psychoacoustics, 637 - Two competing loudness models predict time-variant loudness by peak tracking or frame averaging
#expands(0.85) — Ville Pulkki, Matti Karjalainen, Communication Acoustics- An…, 1659 - Perceived loudness of time-varying sounds tracks near-peak levels, not averages
#qualifies(0.80) - Different hearing tasks exploit different model time constants.
#responds-to(0.75) — Ville Pulkki, Matti Karjalainen, Communication Acoustics- An…, 1628
Similar Claims
- Sound level meters need time averaging to estimate varying pressure levels (similarity 0.93)
- Slow and fast meter responses trade averaging for capturing rapid level changes (similarity 0.91)
- Two competing loudness models predict time-variant loudness by peak tracking or frame averaging (similarity 0.85)
- Different hearing tasks exploit different model time constants. (similarity 0.85)
- Perceived loudness of time-varying sounds tracks near-peak levels, not averages (similarity 0.84)
- Long-term averaging obscures transient attack and release sounds (similarity 0.83)
- Simple loudness models fail on complex signals, prompting time-domain and frame-based successors. (similarity 0.83)
- Loudness meters use frequency weightings as a compromise because ear response varies with level (similarity 0.83)
- A simple high-pass filter can replace elaborate loudness models (similarity 0.82)
- Perceived loudness meters must weight frequencies as a compromise across sound levels. (similarity 0.81)
- Static loudness models fail on time-variant sounds, motivating frame-based temporal integration models (similarity 0.81)
- No single frequency-weighting can accurately meter loudness at all levels (similarity 0.80)
- Modeling time-varying loudness requires emulating temporal integration and post-masking. (similarity 0.80)
- Hearing is highly sensitive to temporal changes in sound (similarity 0.80)
- Time-varying sound loudness is set by integrated loudness peaks, not moment-to-moment level (similarity 0.80)
Mesh connections
- Sound level meters need time averaging to estimate varying pressure levels illuminates this claim — Acoustics and Psychoacoustics
- Time averaging is the mechanism, and the averaging-time constant is why meters trade average accuracy against tracking speed.
- Different hearing tasks exploit different model time constants. illuminates this claim — Communication Acoustics- An Introduction to Speech, Audio and Psychoacoustics
- A explains why different time constants are needed—hearing tasks have different optimal integration windows
- Loudness models need 100-200 ms time constants to capture temporal integration and post-masking. corroborates this claim — Communication Acoustics- An Introduction to Speech, Audio and Psychoacoustics
- Both describe temporal integration mechanisms in sound measurement, from perceptual and instrumentation angles