No single frequency-weighting can accurately meter loudness at all levels
Evidence
These effects make it difficult to design a meter which will give a Âreading which truly relates to the perceived loudness of a sound, so an instrument which gives an approximate result is usually used. This is achieved by using the sound pressure level but frequency weighting it to compensate for the variation of sensitivity of the ear as a function of frequency. Clearly the opti mum compensation will depend on the absolute value of the sound pres sure level being measured and so some form of compromise is necessary. — David Howard, Jamie Angus, coustics and Psychoacoustics, 623
Categorization
- SEED: An essay on why every loudness standard (A-weighting, LUFS) is a negotiated fiction rather than a measurement of experience.
- XREF: Connects to Fletcher-Munson equal-loudness contours and to ISO 226 loudness standards. — connects to: Noise annoyance cannot be captured by physical sound parameters alone. — Almo Farina, Soundscape Ecology: Principles,…, 1441; No single acoustic treatment satisfies because satisfaction is multidimensional
- factual_claims: It explains why no fixed weighting works: equal-loudness sensitivity varies with absolute level, forcing a compromise in the meter’s design.
Mesh connections
- Subjective judgment remains the ultimate reference for loudness measurement schemes demonstrates this claim — Sound reproduction- the acoustics and psychoacoustics of loudspeakers and rooms
- The failure of any single weighting scheme proves subjective judgment is needed as ultimate reference metric
- contradicts (both ways) The A-weighting filter is now standard for all sound levels for consistency — Acoustics and Psychoacoustics
- Claim A asserts A-weighting is now standard for all sound levels, while Claim B states no single weighting works accurately at all levels—direct methodological opposition.
- this claim complicates Frequency response is the single most important measurable parameter of audio devices. — Sound reproduction- the acoustics and psychoacoustics of loudspeakers and rooms
- Multi-level loudness metering problem complicates using frequency response alone to assess devices
- Ear sensitivity depends jointly on frequency and on sound level illuminates this claim — Acoustics and Psychoacoustics
- B’s joint frequency-level dependence explains why A’s single-weighting scheme must fail; mechanism clarifies limitation
- A-weighted sound power ratios overestimate perceived loudness differences in noise emissions. exemplifies this claim — Psychoacoustics- Facts and Models
- A-weighting overestimating loudness differences serves as a concrete instance that no single weighting works at all levels
- Broadband factory noise loudness in phons far exceeds its measured dB level exemplifies this claim — Psychoacoustics- Facts and Models
- A’s broadband factory noise shows why B’s claim holds—no weighting captures its phon-dB discrepancy.
- Each listener has a stable, individual weighting of frequencies when hearing speech in noise complicates this claim — Physiology, Psychoacoustics and Cognition in Normal and Impaired Hearing
- Individual weighting variations across listeners complicates achieving universal loudness metering standards.
- corroborates (both ways) Loudness is not reducible to sound pressure level or signal power — Psychoacoustics- Perception of Normal and Impaired Hearing with Audiology Applications
- Both assert loudness cannot be reduced to physical acoustic measures alone, supporting the same conclusion from psychoacoustics.