C-weighting captures low frequencies better at high sound pressures

Evidence

Figure 2.13 shows two frequency weightings which are commonly used to perform this compensation—termed “A” and “C” weightings. The “A” weighting is most appropriate for low amplitude sounds as it broadly com­ pensates for the low-level sensitivity versus frequency curve of the ear. The “C” weighting on the other hand is more suited to sound at higher absolute sound pressure levels and because of this is more sensitive to low-frequency components than the “A” weighting. The sound levels measured using the “A” weighting are often given in the unit dBA, and levels using the “C” weighting in dBA. Despite the fact that it is most appropriate for low sound levels, and is a reasonably good approximation there, the “A” weighting is now recommended for any sound level in order to provide a measure of consistency between measurements. — David Howard, Jamie Angus, coustics and Psychoacoustics, 624

Categorization

  • DEFINE: Clarifies why low frequencies matter more at high levels — tied to the ear’s nonlinear loudness response.
  • definitional_content: It defines the A and C frequency weightings, stating which sound pressure range each compensates for and why A is nonetheless standardized everywhere.
  • XREF: connects to: A-weighting can miss dominant low-frequency energy in broadband sounds; A-weighted sound pressure level misrepresents the loudness of broadband noises; Loudness measures can reveal real improvements A-weighting misses entirely — Professor Dr.-Ing. Hugo Fastl, Professor Dr.-Ing. Eberhard, Psychoacoustics- Facts and Models, 1763 (+1 more)