Speech reception threshold experiments sometimes need extra conditions to reach stable performance
Evidence
Four experiments were conducted to test each filter type (HP or LP) on each source (target or masker). Except for experiment 1 (HP target), each experiment was composed of two sub-experiments of eight conditions because no asymptote was reached with the first set of eight conditions. β Dijk, Pim van, Physiology, Psychoacoustics andβ¦, 3550
Categorization
- XREF: Echoes psychophysical staircase procedures in Fechner-style threshold work, where convergence criteria decide how many trials a block needs.
- craft_and_method: Explains the practical decision to double the condition set when an adaptive run failed to reach asymptote.
Mesh connections
- Response bias distorts threshold measurements in hearing experiments. illuminates this claim β Psychoacoustics- Perception of Normal and Impaired Hearing with Audiology Applications
- Response bias explains why extra conditions are sometimes needed to stabilize SRT performance
- this claim qualifies Speech reception thresholds closely duplicate averaged audiometric thresholds β Psychoacoustics- Perception of Normal and Impaired Hearing with Audiology Applications
- Need for extra conditions in SRT experiments qualifies claim that SRT closely duplicates audiometric thresholds
- this claim extends Speech quality tests need at least 16 naive potential users for statistical power β coustics and Psychoacoustics
- Stable performance in threshold experiments requires the statistical rigor principles that naive user minimums enforce.