Reaction time measures loudness across the full hearing range
Evidence
Because loudness can be difficult to measure, using alternative methods such as reaction time to characterize loudness has value for research and clinical purposes. Certain populations, like animals or people with significant language disabilities, cannot always provide loudness judgments like those described in this chapter. Consequently, using reaction time as a correlate of loudness has been gaining traction in animal models and has proven valuable in establishing animal models for auditory disorders (e.g., Lauer & Dooling, 2007). Reaction time measures are beginning to become more widespread in human testing as well. For example, recent studies have applied reaction time techniques in the development of models of hyperacusis, an increased sensitivity to sounds. Reaction times would be expected to be faster in the presence of hyperacusis (Hébert, Fournier, & Noreña, 2013), and therefore reaction time may provide a fast and reliable way to measure loudness in large groups of people. — Jennifer Lentz, Psychoacoustics- Perception of Normal…, 792
Reaction time is a correlate of loudness that has garnered favor in the past few years, and reaction time has the potential to provide a less subjective correlate of loudness than magnitude estimation. If reaction time, the time it takes to respond to a stimulus, varies in a predictable way with loudness, then reaction time could be used as a fast and possibly more reliable estimate of the loudness of sounds. — Jennifer Lentz, Psychoacoustics- Perception of Normal…, 783
In a detection experiment, the reaction time is defined as the amount of time required for a listener to detect a stimulus (e.g., by pressing a button), and it is generally measured from stimulus onset. … Psychoacoustic detection experiments do not allow this, as the relevant measures for detection are either absolute threshold or percent detection. A typical psychometric function only covers a range of about 10 to 15 dB. Reaction times, on the other hand, can be measured to sounds presented at levels across the full dynamic range of hearing. — Jennifer Lentz, Psychoacoustics- Perception of Normal…, 786
Categorization
- XREF: Directly serves the reading purpose of normal vs impaired hearing — reaction time opens loudness measurement to animals, language-disabled humans, and hyperacusis patients. — connects to: Envelope-following response measures capture hearing aspects beyond the audiometric threshold — Dijk, Pim van, Physiology, Psychoacoustics and…, 5885; Reaction time measures loudness in animals and language-disabled people — Jennifer Lentz, Psychoacoustics- Perception of Normal…, 792
- SEED: Possible essay angle: reaction time as a ‘behavioral biomarker’ connecting animal and human auditory research, bypassing the need for language.
- definitional_content: Reports specific research findings (Lauer & Dooling 2007; Hébert et al. 2013) on reaction time as a loudness proxy in animals, language-impaired people, and hyperacusis models.
- corroborated: 4 independent passages support this claim — Jennifer Lentz, Psychoacoustics- Perception of Normal…, 792; Jennifer Lentz, Psychoacoustics- Perception of Normal…, 783; Jennifer Lentz, Psychoacoustics- Perception of Normal…, 786
Mesh connections
- Psychoacoustics quantifies physical sound signals into perceived auditory attributes extends this claim — Soundscape Ecology: Principles, Patterns, Methods and Applications
- Quantifying physical-to-perceived attributes enables specific measurement techniques like reaction time for loudness.
- this claim corroborates Envelope-following response measures capture hearing aspects beyond the audiometric threshold — Physiology, Psychoacoustics and Cognition in Normal and Impaired Hearing
- Both identify supra-threshold measures as alternatives to threshold-based assessment
- this claim demonstrates Loudness is the sensation most directly tied to sound intensity — Psychoacoustics- Facts and Models
- Reaction time as loudness measure supports the claim that loudness directly tracks intensity.
- this claim qualifies Loudness depends on frequency, angle, duration, and envelope, not just level — Sound reproduction- the acoustics and psychoacoustics of loudspeakers and rooms
- Loudness’s multi-factor dependence complicates the assumption that reaction time purely measures intensity.
- this claim exemplifies A human listener is needed to connect objective sound pressure with perceived loudness — Acoustics and Psychoacoustics
- Reaction time measurement illustrates the need for human listeners to bridge objective and perceived loudness.
- this claim corroborates Perceived loudness can be measured by iterative ratio-matching across subjects — Communication Acoustics- An Introduction to Speech, Audio and Psychoacoustics
- Reaction time and ratio-matching both validate loudness as a measurable perceptual quantity.
- this claim corroborates Loudness measures span quiet, masked, spectral, and temporal domains — Psychoacoustics- Facts and Models
- Reaction time as loudness measure aligns with loudness spanning multiple measurement domains.
- Typical individual reaction time is one-tenth of a second corroborates this claim — Deep Listening
- Both establish reaction time as a measurable phenomenon in hearing with approximately 100ms duration, from different disciplinary angles