Interaural coherence measures similarity of ear canal signals

Evidence

Duration thresholds were obtained for detecting a change in interaural correlation (from 0 to 1) in the initial portion of a 1-s broadband (0–10 kHz) noise presented simultaneously to both ears. A three-down, one-up 2AFC procedure with 12 reversals, of which the last eight were used to estimate the threshold, was used. — Dijk, Pim van, Physiology, Psychoacoustics and…, 1240 (#expands, via linked claim)

Besides overall hearing sensitivity we also obtained a suprathreshold measure of temporal processing by measuring the sensitivity to change in interaural correlation. This task is assumed to estimate loss of neural synchrony in the auditory system (Wang et al. 2011 ), which in turn has been suggested to affect SiN perception. — Dijk, Pim van, Physiology, Psychoacoustics and…, 1230 (#expands, via linked claim)

Categorization

  • XREF: connects to: Interaural correlation-change detection is a viable temporal processing measure — Dijk, Pim van, Physiology, Psychoacoustics and…, 1240; Sensitivity to interaural correlation change estimates loss of neural synchrony — Dijk, Pim van, Physiology, Psychoacoustics and…, 1230; Inter-channel coherence ICC measures signal similarity normalized from 0 to 1 (+1 more)

Broader Connections