Anodic and cathodic cochlear implant stimulation differ in efficiency between humans and animals
Evidence
While at hearing threshold, no consistent difference between polarities has been observed, a large number of studies have reported that anodic stimulation is more effective than cathodic stimulation at suprathreshold levels (Macherey et al. 2006 , 2008 ; Undurraga et al. 2013 ; Carlyon et al. 2013 ). — Dijk, Pim van, Physiology, Psychoacoustics and…, 2275 (
#expands, via linked claim)
Categorization
- XREF: connects to: Anodic current outperforms cathodic current in human cochlear implant users at suprathreshold levels — Dijk, Pim van, Physiology, Psychoacoustics and…, 2275; Anodic stimulation exceeds cathodic at suprathreshold levels in human CI users; Neural degeneration over time does not flip cathodic-anodic stimulation efficiency in deafened guinea pigs (+5 more)
Related
- Anodic current outperforms cathodic current in human cochlear implant users at suprathreshold levels (similarity 0.94)
- Anodic stimulation is more effective in human implant users but less effective in animals (similarity 0.94)
- Anodic stimulation exceeds cathodic at suprathreshold levels in human CI users (similarity 0.93)
- Never degeneration of neural peripheral processes may explain human anodic stimulation preference (similarity 0.93)
- Cathodic pulses are more efficient in animals but anodic pulses in humans (similarity 0.90)
- Cathodic pulse superiority holds across all four tested pulse shapes (similarity 0.89)
- Neural degeneration cannot explain why anodic stimulation suits humans but cathodic suits animals (similarity 0.89)
- Cathodic action potentials may block centrally at high current, explaining polarity effects (similarity 0.87)
- Some cathodic responses decrease as current rises, growing non-monotonically (similarity 0.87)
- Cathodic pulses produce larger cochlear implant responses than anodic pulses across pulse shapes (similarity 0.87)
- Neural degeneration over time does not flip cathodic-anodic stimulation efficiency in deafened guinea pigs (similarity 0.87)
- Cochlear implant input-output responses can reverse polarity preference at high levels (similarity 0.87)
- Neural degeneration alone does not explain polarity sensitivity differences in cochlear implants (similarity 0.87)
- Cathodic pulses evoke larger inferior colliculus responses than anodic pulses (similarity 0.87)
- Neural degeneration does not drive the anodic sensitivity seen in humans (similarity 0.84)
Broader Connections
- Anodic current outperforms cathodic current in human cochlear implant users at suprathreshold levels
#expands(0.95) — Dijk, Pim van, Physiology, Psychoacoustics and…, 2275 - Anodic stimulation exceeds cathodic at suprathreshold levels in human CI users
#expands(0.90) - Neural degeneration over time does not flip cathodic-anodic stimulation efficiency in deafened guinea pigs
#qualifies(0.80) - Cathodic pulses evoke larger inferior colliculus responses than anodic pulses
#corroborates(0.80) — Dijk, Pim van, Physiology, Psychoacoustics and…, 2272 - Cochlear implant input-output responses can reverse polarity preference at high levels
#qualifies(0.75)