The pitch-matched electrode pair is not necessarily the best for time sensitivity
Evidence
The matched electrodes are R4.4 (pitch comparison), R6-R8 (best IPTD performance), and R6 (largest BIC amplitude). In contrast to the common assumption that pitch-matched pairs maximize sensitivity to binaural cues, for this subject the pairs with best IPTD sensitivity are 1.6–3.6 electrodes away from (interpolated) electrode identical pitch perception. — Dijk, Pim van, Physiology, Psychoacoustics and…, 1469 (
#corroborates, via linked claim)
In contrast to the common assumption that pitch-matched pairs maximize sensitivity to binaural cues, for this subject the pairs with best IPTD sensitivity are 1.6–3.6 electrodes away from (interpolated) electrode identical pitch perception. — Dijk, Pim van, Physiology, Psychoacoustics and…, 1451 (
#expands, via linked claim)
Categorization
- XREF: connects to: Pitch-matched electrode pairs do not maximize binaural time-difference sensitivity — Dijk, Pim van, Physiology, Psychoacoustics and…, 1469; Interaural time difference thresholds stay flat until 3–6 mm of electrode mismatch — Dijk, Pim van, Physiology, Psychoacoustics and…, 1451; Pitch-matching and binaural-cue methods yield uncorrelated electrode pairings in implant patients — Dijk, Pim van, Physiology, Psychoacoustics and…, 1451 (+2 more)
Broader Connections
- Pitch-matched electrode pairs do not maximize binaural time-difference sensitivity
#corroborates(0.95) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1469 - Binaural cue methods agree on electrode mismatch while pitch matching does not
#expands(0.84) - Pitch-matching and binaural-cue methods yield uncorrelated electrode pairings in implant patients
#expands(0.82) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1451 - Physiological and temporal-precision pairing measures agree while pitch matching does not
#expands(0.80) - Interaural time difference thresholds stay flat until 3–6 mm of electrode mismatch
#qualifies(0.78) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1451
Similar Claims
- Pitch-matched electrode pairs do not maximize binaural time-difference sensitivity (similarity 0.94)
- Physiological and temporal-precision pairing measures agree while pitch matching does not (similarity 0.93)
- Pitch-matching and binaural-cue methods yield uncorrelated electrode pairings in implant patients (similarity 0.90)
- Physiological and behavioral binaural measures agree with each other but not with pitch matching. (similarity 0.87)
- Interaural time difference thresholds stay flat until 3–6 mm of electrode mismatch (similarity 0.86)
- Binaural cue methods agree on electrode mismatch while pitch matching does not (similarity 0.86)
- Three electrode-pairing methods give inconsistent results across individual implant users (similarity 0.86)
- Interaural place-of-stimulation mismatch shrinks the binaural interaction component’s magnitude. (similarity 0.83)
- Binaural brainstem neurons compare only interaurally place-matched inputs. (similarity 0.83)
- BIC-based electrode pairing is validated against psychoacoustic pitch and timing measures (similarity 0.83)
- Binaural interaction components show statistically significant electrode tuning in humans (similarity 0.83)
- Pitch-based electrode matching in cochlear implants is confounded by acclimatization and brain plasticity (similarity 0.82)
- BIC amplitude does not correlate with interaural pitch comparison outcomes. (similarity 0.82)
- Perceptual pitch ranking and direct electrical stimulation yield concordant electrode discrimination (similarity 0.80)
- Acoustic and direct-electrode pitch rankings correlate strongly across CI users (similarity 0.79)