SOAE bouncing is not caused by the probe blocking the ear canal
Evidence
Although the observed pattern of synchronized SOAE frequencyand amplitude changes is incompatible with the SOAE bouncing being elicited by changes in middle ear impedance, it is conceivable that bouncing may be only seen in the closed sound field where the auditory meatus is blocked by the OAE probe. Here, we recorded SOAEs in the open meatus using an ER10C probe microphone fitted to the meatus via an about 8 cm silicon tube (2.8 mm outer diameter) which did not block the meatus. The tip of the tube was positioned about 10 mm in front of the tympanum. LF exposure was provided by two powerful custom-made subwoofers. Subjects lay on a deck chair in a long basement corridor at a point where standing waves in the corridor maximised the sound level at 30 Hz. LF exposure was 118 dB SPL for 90 s. β Dijk, Pim van, Physiology, Psychoacoustics andβ¦, 3711