Only 20 percent of speech T-F units exceed minus 4 dB local SNR
Evidence
The ITFS studies found a decrease in target speech intelligibility for SNR criteria exceeding the global SNR of the mixture by 5-10 dB, similar to the local SNR value of about 0 dB (i.e. around 10 dB above global SNR) in our study. An analysis of the local SNRs of all T-F units in ten unfiltered stimuli (see Fig. 3 ) was performed to determine the proportion of T-F units exceeding a certain SNR level. The analysis reveals that on average only about 20 % of the total target T-F units exceeded a local SNR value of -4 dB and about 7 % exceeded a value of 10 dB SNR. — Dijk, Pim van, Physiology, Psychoacoustics and…, 1661 (
#corroborates, via linked claim)
Although the full functional range of hearing is vast, about 130 dB for the level and 20 Hz to 20 kHz for frequency, a much smaller area of the total range is utilized in practical communication situations. For acoustic music the effective range is about that shaded light grey in Figure 9.2. In speech communication the most basic range is still more limited. — Ville Pulkki, Matti Karjalainen, Communication Acoustics- An…, 983 (
#expands, via linked claim)
Categorization
- XREF: connects to: Only about 20 percent of time-frequency units carry audible target speech — Dijk, Pim van, Physiology, Psychoacoustics and…, 1661; Intelligible speech needs only a small fraction of its time-frequency units; Local SNR is computed per 23 ms one-ERB time-frequency unit — Dijk, Pim van, Physiology, Psychoacoustics and…, 1627 (+1 more)
Broader Connections
- Only about 20 percent of time-frequency units carry audible target speech
#corroborates(0.90) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1661 - Intelligible speech needs only a small fraction of its time-frequency units
#corroborates(0.85) - Practical speech communication uses only a small slice of hearing’s full range
#expands(0.78) — Ville Pulkki, Matti Karjalainen, Communication Acoustics- An…, 983 - Local SNR is computed per 23 ms one-ERB time-frequency unit
#expands(0.75) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1627
Similar Claims
- Only about 20 percent of time-frequency units carry audible target speech (similarity 0.90)
- Only about 20% of target speech time-frequency units are needed for near-normal intelligibility. (similarity 0.90)
- Practical speech communication uses only a small slice of hearing’s full range (similarity 0.85)
- Intelligible speech needs only a small fraction of its time-frequency units (similarity 0.83)
- Speech intelligibility saturates beyond certain signal-to-noise ratio bounds. (similarity 0.83)
- Effective SNR range for speech extends far beyond SII standard bounds. (similarity 0.82)
- The range of SNRs contributing to speech intelligibility is wider than SII standards assume (similarity 0.81)
- Improving the SNR by reducing noise helps speech more than raising the target. (similarity 0.81)
- Local SNR is computed per 23 ms one-ERB time-frequency unit (similarity 0.81)
- Detection threshold for SNR change in sentences averages about 3 dB (similarity 0.80)
- Speech models incorrectly assume uniform SNR importance within fixed floor and ceiling bounds. (similarity 0.80)
- The just noticeable difference in signal-to-noise ratio for speech is about 3 dB (similarity 0.80)
- Local signal-to-noise ratios are computed across both time and frequency dimensions (similarity 0.79)
- Speech reception thresholds plateau beyond a target low-pass attenuation floor (similarity 0.79)
- Every 1 dB of signal-to-noise improvement raises speech intelligibility by 7 to 19 percent (similarity 0.79)