Effective SNR range for speech extends far beyond SII standard bounds.

Evidence

SRTs were not affected any longer beyond a certain attenuation level (floor or ceiling values) and remained constant. The floor/ceiling values observed in these experiments are not in agreement with the SII assumptions, except when the target was HP-filtered. In this specific case, the results suggested a floor value at 13-dB attenuation. The results from the other experiments suggested a larger range of SNRs contributing to speech intelligibility [‑37 dB; 43 dB]. When the target is filtered, the floor value seemed to be frequency-dependent in contrast to the SII approach which proposes the same SNR range in each frequency band. — Dijk, Pim van, Physiology, Psychoacoustics and…, 3536

Categorization

  • QUESTION: SII standard is central to many speech models; worth checking why negative vs positive SNR contribution differs so asymmetrically.
  • contrarian_or_surprising: It contradicts the SII’s fixed per-band SNR range, reporting a far wider contributing span from -37 to +43 dB and frequency-dependent floors.