Model-computed and measured loudness match across the full level range
Evidence
The reason for this effect, also shown in Fig. 8.7, is the flatter upper slope of the excitation pattern, and consequently also the flatter loudness pattern, towards higher critical-band rates. In this case, not only the peak value of the specific-loudness pattern decreases with increasing bandwidth but also the upper slope, with the result that the area is almost constant, i.e. constant loudness, for bandwidths between critical band and octave band at levels near 100 dB SPL. The loudnesses calculated using the model and those measured psychoacoustically are very close to one another; they both show the invariance of loudness for spectral extension within one critical band and the same dependence on bandwidth beyond the critical band. — Professor Dr.-Ing. Hugo Fastl, Professor Dr.-Ing. Eberhard, Psychoacoustics- Facts and Models, 1288
Categorization
- XREF: Model-validation result echoes the tone-versus-noise loudness matching theme from earlier chapters on excitation patterns. — connects to: European multichannel loudness experiments matched listener judgments to model predictions.
- factual_claims: It reports that model-calculated and psychoacoustically measured loudness agree closely, both showing loudness invariance within one critical band and identical bandwidth dependence beyond it.
Mesh connections
- this claim demonstrates Loudness models can guide hearing aid programming and alarm design — Psychoacoustics- Perception of Normal and Impaired Hearing with Audiology Applications
- A validates model accuracy across levels, which justifies B’s use in practical applications
- this claim contradicts Psychoacoustic loudness models cannot accurately predict individual listener responses — Sound reproduction- the acoustics and psychoacoustics of loudspeakers and rooms
- B contradicts A’s claim that psychoacoustic loudness models cannot accurately predict individual responses by asserting that model-computed and measured loudness do match.
- Computational auditory models serve knowledge, audio-quality measurement, and diagnostics exemplifies this claim — Communication Acoustics- An Introduction to Speech, Audio and Psychoacoustics
- Loudness matches across the full level range are a concrete case of computational auditory models serving knowledge and audio-quality measurement.
- this claim demonstrates Loudness is not reducible to sound pressure level or signal power — Psychoacoustics- Perception of Normal and Impaired Hearing with Audiology Applications
- Measurement and computation data shows loudness varies independently of simple physical metrics
- this claim illuminates PAQM estimates audible quality degradation by comparing specific loudness across critical bands. — Communication Acoustics- An Introduction to Speech, Audio and Psychoacoustics
- Validation that computed loudness matches measured loudness across level range supports PAQM’s loudness-based degradation estimates.