Deactivating multiple cochlear implant electrodes can worsen rather than improve hearing
Evidence
If a poor ENI arises due to an underlying neural dead region, the transmission of information in that frequency channel could be impeded; if a poor ENI arises due to the presence of broad electrical fields, this will lead to corruption of channel specific information. For both cases it could be beneficial to deactivate electrodes, however when doing so frequency information is re-allocated to other electrodes making analysis bands broader and distorting frequency-to-electrode mapping. These effects are small for individual electrode deactivation but can be substantial for deactivation of multiple electrodes, potentially resulting in poorer precision of information transmission; a completely opposite effect to that intended. — Dijk, Pim van, Physiology, Psychoacoustics and…, 2051
Categorization
Category: Causal Relationships
Related
- Deactivating multiple electrodes can worsen rather than improve information precision. (similarity 0.91)
- Cochlear implant re-mapping deactivates poorly placed electrodes to improve spectral resolution. (similarity 0.90)
- Deactivating electrodes can shift frequency-to-electrode mapping and worsen perception (similarity 0.90)
- Electrode deactivation reallocates frequencies and can harm rather than help (similarity 0.88)
- Deactivating an electrode shifts frequency-to-electrode allocation and can negate expected benefits. (similarity 0.88)
- Deactivating multiple implant electrodes can worsen frequency information transmission (similarity 0.88)
- Deactivating indiscriminable implant electrodes fails to improve and even worsens perception (similarity 0.85)
- Electrode deactivation worsens spectral resolution despite unchanged stimulation rate (similarity 0.85)
- Deactivating non-distinct cochlear implant electrodes fails to improve speech perception (similarity 0.85)
- Cochlear implant electrode deactivation produces inconclusive and strategy-dependent results (similarity 0.84)
- Only half of cochlear implant users benefit from electrode deactivation, and many worsen. (similarity 0.84)
- Electrode deactivation outcomes depend on stimulation rate and filter allocation differences (similarity 0.83)
- Deactivating pitch-indiscriminable cochlear implant electrodes yields no speech benefit (similarity 0.83)
- Pitch-ranking-based electrode deactivation provides no measurable benefit for ACE implant users. (similarity 0.82)
- N-of-m cochlear processing strategies resist benefit from electrode deactivation (similarity 0.82)