Reverberation time can be predicted by summing each surface’s equivalent open-window absorption per frequency band.

Evidence

Using the data in Table 6.1, set up a spreadsheet or table, as shown in Table 6.2, and calculate the equivalent open window area for each surface as a function of frequency. Having done that, add up the individual surface contributions for each frequency band and apply Equation 6.20 to the result in order to calculate the reverberation time. — David M. Howard, Jamie Angus, Acoustics and Psychoacoustics, 1895

Categorization

  • DEFINE: Introduces the ‘equivalent open window area’ — Sabine’s absorption unit — as the operational quantity in room-acoustics prediction.
  • craft_and_method: The passage gives a procedure: build a table, calculate each surface’s equivalent open window area per frequency band, sum the surfaces per band, then apply Equation 6.20 to get the reverberation time.