Post-masking depends on masker bandwidth as well as duration

Evidence

When using narrow-band maskers, post-masking also depends on bandwidth. Therefore, many variables besides the levels of the two maskers influence the addition of the effects produced by masker ā€œIā€ and masker ā€œ2ā€. One example that produces relatively large effects will be discussed. Both the maskers are relatively long (about 500 ms); the test-tone duration is 20 ms and Gaussianshaped, with a 2-ms rise time. The delay time between the end of the masker and the end of the test tone is kept constant at 46 ms. A narrow-band noise centred at 2.8 kHz is llsed as masker Ml. The frequency of the testtone burst is the same as the centre frequency of masker Ml. Masker M2 is a sinusoidal tone at 3.22 kHz (Fig. 4.40a) or a broad-band noise (Fig. 4.40b). — Professor Dr.-Ing. Hugo Fastl, Professor Dr.-Ing. Eberhard, Psychoacoustics- Facts and Models, 626

Categorization

  • XREF: Extends earlier post-masking duration findings into the bandwidth dimension, connecting to the excitation-pattern framework.