Leq reduces varying noise to an equivalent constant sound level
Evidence
This measure integrates the instantaneous squared pressure over some time interval, such as 15 min or 8 h, and then takes the square root of the result. This provides an estimate of the root mean square level of the signal over the time period of the measurement and so gives the equivalent sound level for the time period. That is, the output of the Leq measurement is the constant sound pressure level, which is equivalent to the varying sound level over the measurement period. The Leq measurement also provides a means of estimating the total energy in the signal by squaring its output. A series of Leq measurements over short times can also be easily combined to provide a longer-time Leq measurement by simply squaring the individual results, adding them together and then taking the square root of the result, as shown in Equation 2.7. — David M. Howard, Jamie Angus, Acoustics and Psychoacoustics, 639
Categorization
- DEFINE: Explains the mathematical principle — root-mean-square integration — behind the equivalent continuous sound level.
- definitional_content: It defines Leq as the constant sound pressure level equivalent to a varying sound over a measurement period, and how short Leqs combine.
- XREF: connects to: Leq integrates squared pressure over time to yield an equivalent constant sound level — David Howard, Jamie Angus, coustics and Psychoacoustics, 629; Leq integrates squared pressure over time to estimate noise exposure
Broader Connections
- Leq integrates squared pressure over time to yield an equivalent constant sound level
#expands(0.95) — David Howard, Jamie Angus, coustics and Psychoacoustics, 629 - Leq integrates squared pressure over time to estimate noise exposure
#corroborates(0.90)
Similar Claims
- Leq integrates squared pressure over time to yield an equivalent constant sound level (similarity 0.97)
- Leq measurement integrates squared pressure to yield an equivalent constant level (similarity 0.96)
- Leq integrates squared pressure over time to estimate noise exposure (similarity 0.94)
- Leq measurements assess cumulative noise exposure linked to hearing loss (similarity 0.83)
- Measuring noise exposure over time requires Leq, not standard meter settings (similarity 0.81)
- Sound amplitude is measured as root mean square pressure because ears sense pressure (similarity 0.80)
- Sound level meters need time averaging to estimate varying pressure levels (similarity 0.80)
- Noise exposure is measured as an integrated dose, trading level against duration (similarity 0.78)
Mesh connections
- Squaring the pressure signal makes noise and reverberation measurable on a common scale illuminates this claim — Communication Acoustics- An Introduction to Speech, Audio and Psychoacoustics
- A explains the mathematical rationale (squaring pressure) that makes B’s Leq possible
- this claim extends Sound level meters measure pressure, from which intensity is derived — Psychoacoustics- Perception of Normal and Impaired Hearing with Audiology Applications
- B builds on A’s pressure measurement to derive integrated equivalent level