IPD detection worsens with age even when audiograms stay normal
Evidence
Füllgrabe et al. ( 2015 ) eliminated confounding effects of hearing loss by testing young (18–27 years) and older (60–79 years) subjects with matched audiograms. Both groups had audiometric thresholds ≤ 20 dB HL from 0.125 to 6 kHz. The TFS1 test was conducted using centre frequencies of 1 and 2 kHz. The older subjects performed significantly more poorly than the young subjects for both centre frequencies. Performance on the TFS1 task was not correlated with audiometric thresholds at the test frequencies. These results confirm that increased age is associated with a poorer ability to use monaural TFS cues, in the absence of any abnormality in the audiogram. — Dijk, Pim van, Physiology, Psychoacoustics and…, 793 (
#corroborates, via linked claim)
Moore et al. ( 2012 ) tested 35 subjects with audiometric thresholds ≤ 20 dB HL from 0.25 to 6 kHz and ages from 22 to 61 years. The TFS-LF test was used at center frequencies of 500 and 850 Hz. There were significant correlations between age and IPD thresholds at both 500 Hz (r = 0.37) and 850 Hz (r = 0.65). Scores on the TFS-LF task were not significantly correlated with absolute thresholds at the test frequency. These results confirm those of Ross et al. ( 2007 ) and Grose and Mamo ( 2010 ), and indicate that the decline in sensitivity to binaural TFS with increasing age is already apparent by middle age. — Dijk, Pim van, Physiology, Psychoacoustics and…, 793 (
#corroborates, via linked claim)
It is widely believed that the difference limen for frequency (DLF) of pure tones depends on the use of TFS information for frequencies up to 4-5 kHz (Moore 1973 ), and perhaps even up to 8 kHz (Moore and Ernst 2012 ). If so, the DLF at low and medium frequencies provides a measure of TFS processing. Abel et al. ( 1990 ) and He et al. ( 1998 ) compared DLFs for young and older subjects with normal hearing (audiometric thresholds ≤20 dB HL from 0.25 to 4 kHz). In both studies, DLFs were larger by a factor of 2-4 for the older than for the younger subjects, suggesting that there is an effect of age. However, performance on other tasks (duration discrimination for Abel et al. and intensity discrimination for He et al.) was also poorer for the older group, suggesting that there may be a general effect of age that leads to reduced “processing efficiency”. The effect of age cannot be attributed to reduced frequency selectivity, since auditory filters do not broaden with increasing age when absolute thresholds remain normal (Lutman et al. — Dijk, Pim van, Physiology, Psychoacoustics and…, 798 (
#corroborates, via linked claim)
Categorization
- XREF: connects to: Temporal-structure sensitivity declines with age even when audiograms remain normal. — Dijk, Pim van, Physiology, Psychoacoustics and…, 793; Frequency discrimination worsens with age even when audiometric thresholds stay normal — Dijk, Pim van, Physiology, Psychoacoustics and…, 798; Binaural TFS sensitivity declines with age even when audiograms are normal — Dijk, Pim van, Physiology, Psychoacoustics and…, 793 (+6 more)
Broader Connections
- Temporal-structure sensitivity declines with age even when audiograms remain normal.
#corroborates(0.92) — Dijk, Pim van, Physiology, Psychoacoustics and…, 793 - Binaural TFS sensitivity declines with age even when audiograms are normal
#corroborates(0.90) — Dijk, Pim van, Physiology, Psychoacoustics and…, 793 - Frequency discrimination worsens with age even when audiometric thresholds stay normal
#corroborates(0.88) — Dijk, Pim van, Physiology, Psychoacoustics and…, 798 - Early-elderly listeners show temporal sensitivity decline before audiometric loss appears.
#corroborates(0.85) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1029 - Age-related hearing decline begins even with clinically normal pure-tone audiograms
#expands(0.82) — Dijk, Pim van, Physiology, Psychoacoustics and…, 4155 - Age-related hearing decline in noise begins while thresholds remain normal
#corroborates(0.80) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1140 - Clinically normal hearing still shows age-linked decline that affects speech perception
#corroborates(0.78) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1138 - Hearing sensitivity within clinically normal range still declines measurably with age
#qualifies(0.75) — Dijk, Pim van, Physiology, Psychoacoustics and…, 1140 - Age and hearing loss damage TFS but spare envelope cue processing
#complicates(0.72)
Similar Claims
- Frequency selectivity, not temporal processing, drives age-related declines in Huggins-pitch thresholds. (similarity 0.90)
- Binaural temporal fine structure sensitivity declines by middle age independently of hearing thresholds (similarity 0.90)
- Sensitivity to interaural phase difference declines measurably by middle age. (similarity 0.89)
- Temporal-structure sensitivity declines with age even when audiograms remain normal. (similarity 0.89)
- Monaural temporal fine structure processing declines with age even without hearing loss. (similarity 0.89)
- Age and hearing loss damage TFS but spare envelope cue processing (similarity 0.89)
- Aging degrades envelope-based binaural phase discrimination independent of hearing loss (similarity 0.89)
- Binaural TFS sensitivity declines with age even when audiograms are normal (similarity 0.87)
- Frequency discrimination thresholds are 2-4 times worse in older adults with normal audiograms. (similarity 0.87)
- Hearing loss primarily harms monaural TFS processing while age harms binaural TFS processing (similarity 0.86)
- Age-related hearing decline begins even with clinically normal pure-tone audiograms (similarity 0.86)
- Aging reduces envelope processing efficiency but not temporal resolution. (similarity 0.86)
- Frequency discrimination worsens with age even when audiometric thresholds stay normal (similarity 0.85)
- Age-related hearing decline in noise begins while thresholds remain normal (similarity 0.85)
- Normal audiograms correspond to unchanged auditory filter widths with age (similarity 0.85)