Hearing-loss compensation for stimuli is capped beyond 9 kHz due to audiogram limits
Evidence
Compensation for hearing loss was applied. In short, a level corresponding to 60 dB SPL(C) free-field was selected as the presentation level to be used with NH test subjects. For the HI test subjects, it was then ensured that in each one-third octave band the RMS level of the stimulus was at least 15 dB above hearing threshold before pinna-cue shaping. The required gain was added by designing an IIR filter in the test software to shape the stimulus. Note that the + 15-dB gain strategy was terminated at 9 kHz. In higher frequency bands, the same gain as found for 9 kHz was applied, because of the lack of audiogram information. — Dijk, Pim van, Physiology, Psychoacoustics and…, 3061