Coupler type 4.3 shifts both low and high frequency headphone readings
Evidence
The positioning and coupling of the headphone on the ears can produce significant variations in the measured response, particularly at frequencies below 500 Hz and above 3 kHz. Closed-back headphone designs typically require the cushions to properly seal around the ear to reproduce good bass, which can be a challenge for many test fixtures and humans depending on the size and shape of their heads/ears and how well the cushions fit and seal around the ear. — Toole, Floyd E, Sound reproduction- the acoustics and…, 1717 (
#corroborates, via linked claim)
Categorization
- XREF: connects to: Headphone measurement variability is greatest below 500 Hz and above 3 kHz — Toole, Floyd E, Sound reproduction- the acoustics and…, 1717; Headphone positioning causes large measurement variation below 500 Hz and above 3 kHz.; Headphone reproducibility varies strongly with frequency, worse at bass and treble extremes (+2 more)
- yield-rescued: below the book’s yield-target cutoff, included anyway for connecting to: Headphone measurement variability is greatest below 500 Hz and above 3 kHz — Toole, Floyd E, Sound reproduction- the acoustics and…, 1717; Headphone positioning causes large measurement variation below 500 Hz and above 3 kHz.; Headphone reproducibility varies strongly with frequency, worse at bass and treble extremes (+2 more)
Broader Connections
- Headphone measurement variability is greatest below 500 Hz and above 3 kHz
#corroborates(0.82) — Toole, Floyd E, Sound reproduction- the acoustics and…, 1717 - Headphone reproducibility varies strongly with frequency, worse at bass and treble extremes
#expands(0.78) - Headphone positioning causes large measurement variation below 500 Hz and above 3 kHz.
#expands(0.75) - Earphone frequency response must be measured on real ears, not couplers
#complicates(0.74) - Headphone measurements vary most between individuals at high frequencies.
#qualifies(0.72) — Toole, Floyd E, Sound reproduction- the acoustics and…, 1738
Similar Claims
- Headphone measurement variability is greatest below 500 Hz and above 3 kHz (similarity 0.85)
- Earphone frequency response must be measured on real ears, not couplers (similarity 0.85)
- Headphone positioning causes large measurement variation below 500 Hz and above 3 kHz. (similarity 0.85)
- Ear simulator corrections depend on the headphone’s own acoustic load (similarity 0.83)
- Headphone reproducibility varies strongly with frequency, worse at bass and treble extremes (similarity 0.81)
- Ear coupling and head size make headphone sound-quality opinions vary widely (similarity 0.81)
- Head and ear variation makes fixture measurements unreliable predictors of listening (similarity 0.80)
- Impulse response measurements can misrepresent what listeners actually hear (similarity 0.80)
- Headphone measurements vary most between individuals at high frequencies. (similarity 0.80)
- Headphone test-fixture measurements often fail to predict what individual listeners hear (similarity 0.80)
- Head-mounted measurement adds leakage absent from flat-plate fixtures (similarity 0.80)
- Ear-level microphone measurements capture artifacts inaudible to human listeners (similarity 0.80)
- Test fixtures meeting the same standard still differ in headphone measurements. (similarity 0.79)
- Headphone sound quality depends on fit and acoustic seal around the ear (similarity 0.79)
- Pinna geometry alone changes headphone measurements through leakage (similarity 0.79)